4. Cooling systems, heating
Specifications
General parameters
ATTENTION
Design | Thermosiphon with the bladed water pump. Thermostatic adjustment. With a separate broad tank. The fan with the viscous coupling. The additional electric fan joins and switched off by a thermoswitch |
Cooling liquid | mix of soft water (60%) and antifrizny concentrate (40%) |
Antifrizny concentrate | G12 (red color) (do not mix with any other) |
System volume | |
L engines 1.6, 1.8 | 5.0 l |
Concentration of antifreeze in cooling liquid for ensuring frost resistance to | |
– 35 °C | 50% |
– 25 °C | 40% |
Thermostat | |
Temperature of the beginning of opening | 87 °C |
Temperature of full opening | 102 °C |
Valve stroke | not less than 7 mm |
Fan thermoswitch | |
Inclusion/switching off of the 1st step | 92–97/84–91 °C |
Inclusion/switching off of the 2nd step | 99–105/91–98 °C |
Stopper of a broad tank | |
The valve of excessive pressure opens | 1.4–1.6 bar |
The valve of depression opens | 0.06–0.1 bar |
Conditioner coolant | |
Type | R134a |
Volume, гр. | 750 ± 50 |
Refrigerator oil | |
G052 type | 154 A2 |
Volume, cmi | 135 ± 15 |
Efforts of tightening of threaded connections | |
The moments of an inhaling of fixture are given also in the text of the Head and on some illyustratsiyakh*. * The moments of an inhaling highlighted in the text in bold type are subject to exact observance; the efforts which are not highlighted in bold type are given only approximately The water pump on the engine | |
Engines | 15 H m |
Thermostat cover | 15 H m |
Conditioner compressor | 45 H m |